Flow Calculator

Opening Flow Calculator…

Flow CalculatorOpen on desktop ↗

Flow Calculator

LIQUID HYDRAULICS / v1.0

Changing units converts existing values. Length units apply to pipe length, elevation, weir dimensions and head results.

Liquid properties

Pipe & available energy

Large upstream reservoir → full pipe outlet. Positive elevation is downhill. ΣK excludes outlet velocity; an entrance K = 0.5 is the default. Use pressures with the same reference.

Equations, assumptions & references

Pipe: H = Δp/(ρg) + Δz; H = (1 + ΣK + fL/D)v²/(2g); Q = Av. The ideal comparison uses v = √(2gH), with no friction or fittings. Darcy f = 64/Re below Re 2000, Swamee–Jain above 4000, and a smooth interpolation between. Transition estimates are uncertain.

Rectangular: Q = Cd (2/3)b√(2g)h3/2. V-notch: Q = Cd (8/15)tan(θ/2)√(2g)h5/2. Ideal weir flow uses Cd = 1. Density cancels from these gravity-flow equations; viscosity and temperature do not directly correct weir discharge.

Water density and viscosity use linear interpolation of approximate 10 °C table values from 0–90 °C near atmospheric pressure. Custom liquid properties must be supplied at the entered temperature. No gas, non-Newtonian, boiling, cavitation, partially full pipe, or pump-curve model. Estimates for comparison, not a calibrated meter or design certification.

References: EPA EPANET (pipe loss methods) · USBR Water Measurement Manual (thin-plate weirs).