Electronics Calculator
Opening Electronics Calculator…
Lab Boy Calculator
Ohm’s law
Enter any two positive DC quantities to solve voltage, current, resistance and power.
V = I × R · P = V × I. Positive magnitudes for a resistive DC load; zero-valued pairs can be indeterminate.
Voltage divider
Compare the unloaded output with an optional parallel load.
Vout = Vin × (R2 ∥ RL) / [R1 + (R2 ∥ RL)]. A 0 Ω load represents a short circuit. Ideal DC resistors.
555 timer
Explore standard astable timing or a monostable pulse.
Astable: tH = ln(2)(RA + RB)C, tL = ln(2)RB C. Monostable: t = ln(3)RC. Ideal threshold model; component tolerances and device limits affect actual timing. Standard astable duty is above 50%. TI NE555 datasheet ↗
LED resistor
Size one resistor for a single series string of LEDs.
R = (Vs − N × Vf) / I. The preferred resistance rounds upward. Power rating shown is at least twice the nominal dissipation; check tolerances, thermal derating and the LED datasheet. Give each parallel string its own resistor.
Resistor color code
Decode 3-, 4-, 5- or 6-band resistors. Each color is labeled with its role.
Color code reference chart
| Color | Digit | Multiplier | Tolerance | TCR · ppm/°C |
|---|---|---|---|---|
| black | 0 | 10^0 | — | — |
| brown | 1 | 10^1 | ±1% | 100 |
| red | 2 | 10^2 | ±2% | 50 |
| orange | 3 | 10^3 | — | 15 |
| yellow | 4 | 10^4 | — | 25 |
| green | 5 | 10^5 | ±0.5% | — |
| blue | 6 | 10^6 | ±0.25% | 10 |
| violet | 7 | 10^7 | ±0.1% | 5 |
| grey | 8 | 10^8 | ±0.05% | — |
| white | 9 | 10^9 | — | — |
| gold | — | 0.1 | ±5% | — |
| silver | — | 0.01 | ±10% | — |
| No band | — | — | ±20% | — |
Read from the end with the tightly grouped digit bands; the tolerance band is normally separated. Three bands imply ±20%. Six-band mode uses the Vishay TCR convention; check the datasheet for other markings. Vishay color code reference ↗
AWG wire gauge
Round solid wire dimensions and an ideal copper loop voltage-drop estimate.
Full AWG chart · 4/0 to 40
Round solid conductor; IACS annealed copper at 20°C, ρ = 0.017241 Ω·mm²/m. Loop length is twice the one-way length. Stranding, connections and temperature change resistance. This chart does not specify ampacity. NBS copper wire tables ↗
Battery charger planner
Scale a named manufacturer voltage profile and estimate ideal charge throughput.
Confirm the battery datasheet before configuring a charger. Voltage is one part of a chemistry-appropriate charging algorithm and protection system. Current is your assumption, not a recommended safe limit. Ideal Ah ÷ A time excludes taper, losses, balancing, temperature effects and connected loads.
PWM square-wave scope
An interactive ideal signal. Change timing, levels and phase, then inspect the waveform.
T = 1/f · tH = duty × T · Vavg = Vlow + duty × (Vhigh − Vlow). RMS includes the DC component. Phase delays the pulse train. The graph is time-scaled, with ideal instantaneous edges.